Psc QS2500 Manual de usuario

Busca en linea o descarga Manual de usuario para Escáneres Psc QS2500. PSC QS2500 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Product Reference Guide

QuickScan® QS2500Handheld Bar Code ScannerProduct Reference Guide

Pagina 2

6 QS2500Numeric Key: If your application accepts only keypad numeric code, use setting 01 to make the QS2500 output code as numeric-keypad presses whe

Pagina 3 - i

Product Reference Guide 7 Option Bar Code OptionAlphanumeric EntryFunction KeyDisable 00*Enable 01Numeric KeyAlphabetic key

Pagina 4

8 QS2500Wand Emulation NOTESSupport for wand emulation is available only with the keyboardwedge interface. Use the bar codes below to enable and confi

Pagina 5 - Installation

Product Reference Guide 9Margin Delay (pixels)15 (Default)00–99 (x 10 pixels)15*00–99Transmit Delay (Milliseconds)30 (defau

Pagina 6 - 2 QS2500

10 QS2500RS-232CTS = Clear To Send (Hardware Signal)RTS = Request To Send (Hardware Signal)Xon = Transmit On (ASCII Code 11hex)Xoff = Transmit Off (AS

Pagina 7 - Programming the QS2500

Product Reference Guide 11RS-232 Advanced FeaturesFlow ControlNone: The communication uses only TxD and RxD signals, withou

Pagina 8 - Interfaces

12 QS2500RS-232 Advanced Features — continuedResponse DelayThis delay is used for serial communication. It is the amount of time the QS2500 waits for

Pagina 9 - 5

Product Reference Guide 13IBM Interface (46XX/USB)The next few pages contain the programming labels for configuring the IBM

Pagina 10 - 6 QS2500

14 QS2500IBM OptionsIBM 46xx Code 39 ConversionThis feature enables/disables the scanner’s ability to set the symbology identifier for the specified s

Pagina 11 - Alphanumeric

Product Reference Guide 15IBM Host CommandsSpecifies whether the scanner will process or ignore IBM host commands.Option Ba

Pagina 12 - Wand Emulation

PSC Inc959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No part of the cont

Pagina 13 - 9

16 QS2500ScanningScanning ModeGood-read off: The trigger button must be pressed to activate scanning. The light source of the QS2500 stops scanning wh

Pagina 14 - 10 QS2500

Product Reference Guide 17Double ConfirmIf this option is enabled, the QS2500 will require a several successful decodings t

Pagina 15 - RS-232 Advanced Features

18 QS2500Global Minimum/Maximum Code Length: Global minimum and maximum length can be set to qualify data entry. The length is defined as the actual b

Pagina 16 - 12 QS2500

Product Reference Guide 19 Inverted Image Scan: With this option enabled, the QS2500 will scan black/white bar codes with a

Pagina 17

20 QS2500Beep/Tone/LED SettingsPower-On Alert: After power-on, the QS2500 will generate an alert signal to indicate a successful self-test.LED Control

Pagina 18 - IBM Options

Product Reference Guide 21 Option Bar Code OptionAlphanumeric EntryPower-On AlertDisable 00Enable 01*LED IndicationDisable

Pagina 19

22 QS2500Label Editing (includes Prefix/Suffix)Prefix Characters: Up to 22 ASCII characters may be sent before data.Suffix Characters: Up to 22 ASCII

Pagina 20 - Scanning

Product Reference Guide 234. Scan the Store Settings bar code on the inside back cover.5. Repeat the same procedure for the

Pagina 21 - Multifield Scan

24 QS2500Preamble Transmission: The preamble will be appended before the code data.Postamble Transmission: The postamble will be appended after the co

Pagina 22 - 18 QS2500

Product Reference Guide 25 Code ID Transmission: Enable this option to transmit the code ID. See page 27.Code Length Transm

Pagina 23

Product Reference Guide iInstallation ...

Pagina 24 - Beep/Tone/LED Settings

26 QS2500Code Name Transmission: This function is used to show unknown bar code symbologies that include all readable symbologies of the QS2500. The c

Pagina 25 - 21

Product Reference Guide 27Symbology SettingsUPC-ARead: Format:Checksum Transmission: With this option enabled, the QS2500 w

Pagina 26 - : Bar code: “1 2 3 4 5 6”

28 QS2500 Option Bar Code OptionAlphanumeric EntryReadDisable 00Enable 01*Checksum VerificationDisable 00Enable 01*Checksum TransmissionDisable 00Enab

Pagina 27 - 23

Product Reference Guide 29UPC-ERead: Format:Checksum Transmission: When this option is enabled, the QS2500 will transmit th

Pagina 28 - 24 QS2500

30 QS2500 Option Bar Code OptionAlphanumeric EntryReadDisable 00Enable01*Checksum VerificationDisable 00Enable01*Checksum TransmissionDisable 00Enable

Pagina 29 - 25

Product Reference Guide 31EAN-13Read: Format:Checksum Transmission: When this option is enabled, the QS2500 will transmit t

Pagina 30 - 26 QS2500

32 QS2500Checksum TransmissionDisable 00Enable 01*Truncate Leading0–1500–1500*Truncate Ending0–1500–1500*Code ID Setting00–ffH ASCII code00–ffhex<F

Pagina 31 - Symbology Settings

Product Reference Guide 33EAN-8Read: Format:Checksum Transmission: When this option is enabled, the QS2500 will transmit th

Pagina 32 - 28 QS2500

34 QS2500Checksum VerificationDisable 00Enable 01*Checksum TransmissionDisable 00Enable 01*Truncate Leading0–1500–1500*Truncate Ending0–1500–1500*Code

Pagina 33 - 29

Product Reference Guide 35Code 39Read: Format:Checksum Verification: The checksum is optional and presented as the sum mod

Pagina 34 - 30 QS2500

ii QS2500PDF417 ...57Italian PharmaCode ...

Pagina 35

36 QS2500Append: This function allows several symbols to be concatenated and be treated as a single entry. The QS2500 will not transmit the embedded a

Pagina 36 - 32 QS2500

Product Reference Guide 37Interleaved 2 of 5Read: Format:Checksum Verification: The checksum is presented as the sum mod 10

Pagina 37 - 33

38 QS2500 Option Bar Code OptionAlphanumeric EntryReadDisable 00Enable 01*Checksum VerificationDisable 00Enable 01*Checksum TransmissionDisable 00*Ena

Pagina 38 - 34 QS2500

Product Reference Guide 39Industrial 2 of 5Read: Format:Maximum/Minimum Code Length: Same as Code 39. See page 35.Truncate

Pagina 39 - 35

40 QS2500Matrix 2 of 5Read: Format:Checksum Verification: The checksum is presented as the sum mod 10 of the numerical values of all data digits.Check

Pagina 40 - 36 QS2500

Product Reference Guide 41 Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Checksum VerificationDisable 00*

Pagina 41 - Interleaved 2 of 5

42 QS2500CodabarRead: Format:Checksum Verification: The checksum is presented as the sum mod 16 of the numerical values of all data digits.Checksum Tr

Pagina 42 - 38 QS2500

Product Reference Guide 43Max. Code LengthUse Global Max. 00*1–64 01–64Min. Code LengthUse Global Min. 00*1–64 01–64Truncat

Pagina 43 - Industrial 2 of 5

44 QS2500Code 128Read: Format:Checksum Verification: The checksum is presented as the sum mod 103 of all data digits.Checksum Transmission: When this

Pagina 44 - Matrix 2 of 5

Product Reference Guide 45• Append label data with Concatenation Code <GS> (1Dhex):<]C1> <Label data 1> &

Pagina 45 - 41

Product Reference Guide 1InstallationComplete the following steps for the appropriate interface.Keyboard Wedge1. Turn off t

Pagina 46 - 42 QS2500

46 QS2500Code 93Read: Format:Checksum Verification: The checksum is presented as the sum mod 47 of the numerical values of all data digits.Checksum Tr

Pagina 47 - 43

Product Reference Guide 47 Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Checksum VerificationDisable 00E

Pagina 48 - Code 128

48 QS2500Code 11Read: Format:Checksum Verification: The checksum is presented as the sum mod 11 of all data digits.Checksum Transmission: When this op

Pagina 49 - 45

Product Reference Guide 49MSI/PlesseyRead: Format:Checksum Verification: The MSI/Plessey code has one or two optional check

Pagina 50 - 46 QS2500

50 QS2500Insertion Group Selection: Same as UPC-A. See page 27. Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Checksum VerificationD

Pagina 51 - 47

Product Reference Guide 51UK/PlesseyRead: Format:Checksum Verification: The UK/Plessey code has one or two optional checksu

Pagina 52 - 48 QS2500

52 QS2500 Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Checksum VerificationDisable 00Enable 01*Checksum TransmissionDisable 00*Ena

Pagina 53 - MSI/Plessey

Product Reference Guide 53TelepenRead: Format:Checksum Verification: The checksum is presented as the sum mod 10 or 11 of t

Pagina 54 - 50 QS2500

54 QS2500Standard 2 of 5Read: FormatMaximum/Minimum Code Length: Same as Code 39. See page 35.Truncate Leading/Ending: Same as UPC-A. See page 27.Code

Pagina 55 - UK/Plessey

Product Reference Guide 55 Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Max. Code LengthUse Global Max.

Pagina 56 - 52 QS2500

2 QS2500USB1. Plug the USB cable into the terminal or computer.IBM1. Turn off the terminal or computer.2. Connect the appropriate interface cable to t

Pagina 57 - 53

56 QS2500Code 16KTruncate Leading/Ending: Same as UPC-A. See page 27.Code ID Setting: Same as UPC-A. See page 27.Insertion Group Selection: Same as UP

Pagina 58 - Standard 2 of 5

Product Reference Guide 57PDF417Truncate leading/ending: Same as UPC-A. See page 27.Code ID Setting: Same as UPC-A. See pag

Pagina 59 - 55

58 QS2500Italian PharmaCode Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Truncate Leading0–1500–1500*Truncate Ending0–1500–1500*Cod

Pagina 60 - Code 16K

Product Reference Guide 59RSS Expanded Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Max. Code LengthUse

Pagina 61 - 57

60 QS2500RSS Limited Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01SMax. Code LengthUse Global Max. 00*1–64 01–64Min. Code LengthUse

Pagina 62 - Italian PharmaCode

Product Reference Guide 61RSS-14 Option Bar Code OptionAlphanumeric EntryReadDisable 00*Enable 01Truncate Leading0–1500–150

Pagina 63 - RSS Expanded

62 QS2500Appendix - Default SettingsCode TypeReadEnableChecksumVerificationEnableChecksumTransmissionEnableCodeIDUPC-A AUPC-E EEAN-13 FEAN-8

Pagina 64 - RSS Limited

Product Reference Guide 63Appendix B - Bar Code SamplesUPC-AUPC-EEAN-13EAN-8Code 39XZVInterleaved 2 of 5Industrial 2 of 51

Pagina 65 - 61

64 QS2500Matrix 2 of 5CodabarCode 128Code 93Code 11MSI/PlesseyUK/PlesseyStandard 2 of 5Code 16K456353663A112+BA12345Bcd B67890Bcd 6542156789012367890

Pagina 66 - Appendix - Default Settings

Product Reference Guide 65PDF417Italian PharmaCodeRSS ExpandedRSS LimitedRSS-145498756230H8XL901001234567890500112345678901

Pagina 67 - Appendix B - Bar Code Samples

Product Reference Guide 3Programming the QS2500To program the QS2500, you must scan a series of programming bar codes in th

Pagina 68 - 64 QS2500

66 QS2500Appendix C - ASCII CodesExample: ASCII “CR” = “0D”01010Null NUL DLE1Up F1 SOH DC12Down F2 STX DC23Left F3 ETX DC34Right F4 EOT DC45PgUp F5 EN

Pagina 69 - 549875623

Product Reference Guide 67Example: ASCII “A” = “41”2345670SP 0 @ P ` p1!1AQaq2“2BRbr3#3CScs4$4DTdt5%5EUe u6&6FV f v7‘7G

Pagina 71 - Example: ASCII “A” = “41”

Product Reference Guide 69Appendix D - Parameter Setting ListStart ProgramStandard Parameter Setting ListIf you wish to dis

Pagina 72 - 68 QS2500

70 QS2500Appendix E - Alphanumeric Characters0 A1 B2 C3 D4 E5 F678 Store Settings9 Exit

Pagina 73

DECLARATION OF CONFORMITYPSC hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and St

Pagina 74 - 70 QS2500

Asia PacificPSC Hong KongHong KongTelephone: [852]-2-584-6210Fax: [852]-2-521-0291AustraliaPSC Asia Pacific Pty Ltd.North Ryde, AustraliaTelephone: [

Pagina 75

4 QS2500Resetting the QS2500To return all QS2500 option settings to the factory defaults, scan the fol-lowing two bar codes, in the order shown:Interf

Pagina 76

Product Reference Guide 5 Function Key: When this option is enabled, the QS2500 outputs bar code ASCII values from 01hex to

Comentarios a estos manuales