Product Reference Guide F-7
Code 39
Check character must be included in label data.
Label length including start, stop and check characters and
excluding prefix character must meet requirements imposed by
the main scanner's fixed or variable label length control for this
symbology type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character '*'.
Example : '**Code 39.TEST*'.
Code 39-Pharmacode
Check character must be included in label data.
Label length including start, stop and check characters and
excluding prefix character must meet requirements imposed by
the main scanner's fixed or variable label length control for this
symbology type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character 'p'.
Example: 'p*123456789*'.
I 2 of 5
Check character must be included in label data.
Label length including check characters and excluding prefix
character must meet requirements imposed by the main scanner's
fixed or variable label length control for this symbology type.
Prefix must be an ASCII character 'i'.
Example: 'i0123456789'.