Using a Scanner
52 Falcon
®
DOS Portable Terminals
3. After a short timeout period, the scanner switches to a full scanning
beam and reads the bar code.
• The default timeout period is one-half second.
Release Scan Mode
Release Scan mode provides greater control over the spotting beam:
1. Press and hold the trigger for the scanner to emit a spotting beam.
• The spotting beam stays on for up to 5 seconds until the trigger is
released in Release Scan mode.
2. The scanner switches to a full scanning beam and reads the bar code.
3. Turn off the full scanning beam by pressing and releasing the trigger.
To prevent accidental scanning, both modes require that the scannertrigger is
held down to activate the spotting beam.
Linear Imager
A Linear Imager is one option for the scan engine. Functionally, it is used in
the same manner that you use a Falcon with a laser scanner.
Attaching a Bar Code Reader
If a Falcon 31X or 32X does not have an integrated laser scanner, a bar code
reader can be attached to the connector at the top. The reader’s cable must
have a standard nine-pin squeeze connector at the end.
To attach a bar code reader:
• Match the orientation of the holes on the squeeze connector with the
pins on the Falcon’s connector.
• Push the squeeze connector onto the Falcon’s connector until it is firmly
in place. Refer to
Figure 24.
2314.book Page 52 Wednesday, June 9, 2004 8:30 AM