7-266 Magellan
TM
8500Xt Scanner
MSI/Plessey Length 1
If MSI/Plessey Length Control is set to Fixed-Length decoding, this fea-
ture specifies MSI/Plessey first fixed
length. If MSI/Plessey Length Con-
trol is set to Variable-Length decoding, this feature specifies the minimum
label length.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET MSI/PLESSEY LENGTH 1 below. You’ll
need to cover any unused barcodes on this and the facing page to
en
sure that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that
represent the desired label length. The selectable range for this
option is 4 to 16. P
ad all single digit numbers with a leading zero
to yield a two-digit entry (04-16).
4. Complete the programming seque
nce by scanning the SWITCH
barcode.
SET MSI/PLESSEY LENGTH 1