R44-2018 11
IBM INTERFACES
IBM 4682/92 Port E Interface Selection
Scan this bar code to enable the IBM 468x/9x Port E interface (do not scan the SET
bar code before, or the END bar code after scanning this bar code).
IBM 4682/92 Port E Settings
Data Format: Send As Code 39 — converts bar code data (UPC/EAN, add-ons,
Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending
the data to the host.
These settings are for IBM 4682/92 Port E interface ONLY.
Limit Command Set — tells the scanner to ignore 'enable scanner' and 'disable
scanner' commands sent from the host.
Transmit Unsolicited Status
1
— when enabled, the scanner transmitS a status
message to the host upon receipt of an "SNRM".
SET --------------------------------------------------
-------------- SEND AS CODE 39
DON'T SEND AS CODE 39 ----------------
--------------- ENABLE LIMIT COMMAND SET
DISABLE LIMIT COMMAND SET ------------
--------------- TRANSMIT UNSOLICITED STATUS
DON'T TRANSMIT UNSOLICITED STATUS -------------
----------------------------------------------- END
1 For this IBM interface, the setting for Unsolicited Status is normally Disabled.
DATA FORMAT