Data Mapping Object
PowerNet Twin Client User Guide < 5-3 >
Data Mapping Object
The PowerNet Twin Client Mapping Object can be utilized to send a
keypress every time the string is scanned.
<textstring>=<keystroke>;
<textstring>
is the original text string and <keystroke> is the
keypress to send when the specified text string is scanned. Each line
must end with a semi-colon.
For example, the Data Mapping Object file might look like the
following:
$G$ENT=<ENTER>;
123=<TAB>;
DKTH34=<PF1>;
H$*LK=<PF2>;
Build Data Mapping Object File
To build the Data Mapping Object file, complete the following steps:
1. Verify that the
Scanner tab of the PowerNet Twin Client
Configuration utility is selected.
2. Press the
Edit button next to the Data Mapping Object pull-
down list. (Refer to
Figure 2-10 for an illustration of this screen.)
3. Enter a name for the data mapping object file in the
File Name
field and press the Open button.
4. Define all of the necessary data mapping objects according to the
examples above.
5. After building the data mapping object file, select
Exit from the
File menu.
6. Press the
Yes button to save the data mapping object file.
7. Select the file from the
Data Mapping Object pull-down list.