Extended Commands
< 6-4 > PowerNet Twin Client User Guide
Input Mode
The host application can control which inputs the terminal will accept.
A scanner, keyboard, or both can be accepted.
Input Mode parameters are controlled by sending the following
sequence to the Falcon before opening an input field:
<ESC>[!1; <mode>z.
Table 6-1
Input Mode Parameters
Mode Action Description
0 (de-
fault)
Scan
and
key
Data is initially accepted from either the keyboard or
scanner. Scanning is allowed on a partially keyed
field, which causes the keyed data to be discarded
and the scanned data to be accepted.
1
Scan
or key
Data is initially accepted from either the keyboard or
scanner. Scanning is not allowed on a partially
keyed field. If the operator clears the field then
scanning is again allowed.
2
Scan
only
Data is accepted only from the scanner; the
keyboard is turned off.
3
Key
only
Data is accepted only from the keyboard; the
scanner is turned off.